Analysis of the BCM calibration data taken on 2/5/2022. The uncertainties on the extracted gain coefficients are at the 1% level, and the central values are consistent within uncertainties with the previous analysis that looked at beam on and off data spanning the kinematic settings SBS-4 to SBS-11.